Description

The Dayliff DWV pumps are purpose-built for the transfer of industrial and domestic wastewater containing high levels of solid particles, including threads and fibers.

Dayliff DWV Pump Construction

  • Impeller – Cast Iron
  • Casing – Cast Iron
  • Oil Seal – Nitrile Butadiene Rubber (NBR)

Dayliff DWV Features

The pumps are built for heavy-duty applications and include:

  • Cast Iron Vortex Impeller—lowers the risk of clogging
  • Double mechanical seal—for leak prevention.
  • DWV 05A and DWV 10A are designed with a free-standing installation and come with level switches for automatic operation.
  • DWV 30M and other large models are designed for permanent installation and have discharge connections that match with guide rail mounting.

Each pump comes with a 10 m H07RNF power cable.

Motor Specifications

Pumps are supplied with dry-type 2-pole motors designed for continuous duty. They are provided with integral overload protection and require a remote DOL starter.

Enclosure Class: F
Insulation Class: IP68
Speed: 2900 rpm

OPERATING CONDITIONS

Pumped liquids: Thin, chemically non-aggressive liquids containing suspended particles up to the specified size.
Max. Liquid temperature: +40°C
Max. Operating Depth: 10m

Product Data Sheet
Model Voltage (V) Power Current (A) Max. Particle Size (mm) DN ('') Dimensions (mm) Weight (kg)
HP kW L W H
DWV 05A 1x240 0.5 0.37 3.4 35 2 240 153 406 18
DWV 10A 1 0.75 4.8 240 153 426 19
DWV 30M 3x415 3 2.2 4.6 50 3 395 186 522 37
DWV 50M 5 3.7 7.6 4 428 227 542 41
DWV 75M 7.5 5.5 10.3 472 227 680 61